A Type 1 surge protective device (SPD) is considered at the service entrance when the design accounts for lightning current exposure. A Type 1+2 SPD combines Type 1 and Type 2 functions in one device. The choice depends on the functions required at the main switchboard and how the entrance protection is coordinated with devices at other panels.

Type 1 and Type 1+2 SPDs compared

What to compare Type 1 SPD Type 1+2 SPD
Role at the service entrance Considered as the entrance stage where lightning current exposure is assessed. Considered when the entrance design combines Type 1 and Type 2 functions in one device.
Coordination with other panels The design considers the location of the Type 2 stage and coordination between devices. The design also considers whether distribution boards or sensitive loads need additional protection.
What to check in the quote The declared SPD type, impulse current and voltage protection level. The manufacturer’s declaration for both types and the device’s voltage protection level.

Examples of separate and combined protection stages are described in Phoenix Contact’s guide to surge protection.

When is a Type 1 SPD considered?

At an industrial site with an external lightning protection system, the review can start at the electrical service entrance. The design team looks at lightning current exposure and how power is distributed across the site. If a Type 1 SPD is under consideration at the entrance, existing devices at downstream distribution boards and their coordination are part of the same review.

When is a Type 1+2 SPD considered?

A combined device is an option when both functions are being considered at the main switchboard. If the site has several distribution boards or sensitive loads with their own protection requirements, the review also covers their locations and existing protection. For example, while assessing a combined device at the main board, identify the feeder to an automation panel and any SPDs already installed there.

What information should you gather before requesting a quote?

  • Facility and service entrance. Describe the site, its external lightning protection and the panel’s role. Include an available single-line diagram.
  • Supply and earthing. Note the supply voltage, phase arrangement and earthing arrangement where known.
  • Existing devices and loads. List the SPD models already in the main or downstream panels and the equipment those panels supply.
  • Product documentation. Match the quoted model to its data sheet. Review the declared type, maximum continuous operating voltage (Uc), voltage protection level (Up) and impulse current information with the design team.

For projects with multiple protection stages, see Schneider Electric’s guide to SPD coordination.