How does Surge-Trap® work?

A surge protective device (SPD) presents high impedance during normal operation. When a surge occurs, it limits the voltage and diverts surge current into the earthing path. Thermally protected varistor technology helps the component disconnect safely at the end of its service life.

STZ and STXT compared

Product family Typical location Monitoring
STZ Service entrance, automatic transfer switch and main distribution Status LEDs, phase loss indication, surge counter, audible alarm and dry contact
STXT Distribution and subpanels Per-phase status LEDs and phase loss indication; alarm and dry contact depending on model

Both series are listed as Type 1 SPDs in the manufacturer documents. For the 380/220 V configuration in the brochure, STZ offers 100–300 kA per phase and STXT offers 100 or 200 kA surge current options. These ratings alone do not determine the right device; the supply arrangement and protected equipment must be checked for each project.

Key features

  • Thermally protected varistors help the device disconnect safely at the end of its service life.
  • Per-phase status and phase loss indicators make device condition visible to maintenance teams.
  • The STZ range includes a surge counter, audible alarm and dry contact. STXT alarm and dry contact options vary by model.
  • Devices at the service entrance and downstream distribution points are selected together for the actual electrical arrangement.

A coordinated protection approach

Protection at the service entrance and distribution panels is considered together. Short, appropriately routed connecting conductors matter when limiting the residual voltage seen by equipment. The condition of the earthing system also needs review; earthing monitoring supports that maintenance work.

See the Surge-Trap® brochure for product ranges, options and electrical data.

Where are low-voltage SPDs used?

Data centres, manufacturing plants, energy distribution panels and commercial buildings where outages are costly may need protection from the service entrance through to critical loads. In an industrial facility, the review can cover the main switchboard, subdistribution panels feeding production lines and local panels serving automation or other critical loads. Exposure, the supply and earthing arrangement, and the role of each panel guide the selection.

Read the Type 2 SPD guide for typical distribution panel applications and the points to check during selection.

Frequently asked questions

Will one SPD at the service entrance protect all equipment?

Not always. Protection needs at the service entrance and distribution panels are assessed separately; suitable stages and connections are defined for the project.

Is the highest kA rating always the best choice for a panel?

No. Supply voltage, panel location, connections and the needs of protected equipment matter alongside surge current capacity.

What are the status indicators and alarms for?

They make device condition visible to the maintenance team. An alert prompts an on-site check of the relevant phase and protection module; it does not replace routine maintenance.

A starting point for your role

Procurement team

How can I request the Surge-Trap® brochure?

Request the brochure from the Surge-Trap® entry on the Documents page.

What panel information is useful when selecting a low-voltage SPD?

For an initial review, share the information you have via the contact form.

  • The panel’s location and role, such as the service entrance or a subdistribution panel
  • The supply voltage and earthing arrangement
  • The equipment the panel feeds and the model of any existing SPD

Project lead

How can I reach the related risk assessment service?

See Lightning Risk Assessment for the service approach. The Lightning Risk Calculator is also available as a starting point with initial data.

Where are the service entrance and distribution panel explanations?

The “STZ and STXT compared” and “A coordinated protection approach” sections above bring together the existing product and location descriptions. Follow the brochure link for further details.

Operations and maintenance team

Where are the status indicator and alarm explanations?

The features and frequently asked questions above cover these topics. Follow the Surge-Trap® brochure link to review the available product options.

How can I reach the earthing monitoring content?

The Earthing Monitoring System page includes the related approach and document links. Contact the engineering team to share the existing situation at your facility.

Related content